Listed from the MCP registry; nobody on Odel publishes it.
MCP server for Inductive Automation Ignition: tags, alarms, history, and Perspective
Runs on your machine from its package; the steps are below.
At most: moves money, runs code or commands, deletes data, or sends messages for you.
Odel charges nothing per call. The publisher may charge for its own service.
Runs locally over stdio
This server isn't hosted — your MCP client launches it from a package registry. Use one of the commands below, or drop the config into your client (e.g. Claude Desktop).
Run
uvx ignition-mcp
MCP client config
{
"mcpServers": {
"ignition-mcp": {
"command": "uvx",
"args": [
"ignition-mcp"
]
}
}
}An MCP (Model Context Protocol) server for Inductive Automation Ignition. It gives an AI assistant, Claude Desktop, Claude Code, or any MCP client, structured access to an Ignition gateway: browse and write tags, query history and alarms, manage projects, and deploy full Perspective views.
Tested against Ignition 8.3. 43 tools spanning tags, history, alarms, projects, gateway administration, and Perspective. The server is read-only by default; every write is gated behind an explicit opt-in.
You: "Deploy a Perspective dashboard to a new project called LineOverview with a
gauge bound to [default]Line1/Speed."
Claude: (bootstraps the project, writes the view, wires the tag binding, triggers a scan)
-> https://gateway:8088/data/perspective/client/LineOverview
Ignition 8.3 ships a native REST API, but it doesn't expose live tag values, tag history, alarm
queries, or Perspective view resources. ignition-mcp covers the gap with two transport planes:
/data/api/v1 API, authenticated with an API key, used
for projects, gateway configuration, modules, logs, backups, and Perspective session
diagnostics.mcp-bridge) you install once on the gateway. It
exposes the gateway scripting surface (system.tag.*, system.alarm.*, system.db.*, and
project file I/O) over HMAC-signed HTTP requests.Tools that need the bridge degrade with a clear message if it isn't installed. Run
ignition_diagnose any time to see what's configured and what's missing.
Gateway web UI -> Config -> Security -> API Keys -> Create. Give it a name, for example claude.
Copy the full token; it looks like claude:AbCd....
The key's auto-created security level (Authenticated/<key-name>) needs to be granted gateway
read/write access under Config -> Security -> General -> Gateway Read/Write Permissions. Skip
this step and calls return HTTP 403; ignition_diagnose will tell you and give the exact fix.
pipx install ignition-mcp
# or: uvx ignition-mcp
# or: pip install ignition-mcp
Claude Desktop (claude_desktop_config.json) or Claude Code (.mcp.json):
{
"mcpServers": {
"ignition": {
"command": "ignition-mcp",
"env": {
"IGNITION_URL": "http://localhost:8088",
"IGNITION_API_TOKEN": "claude:YOUR_SECRET_HERE"
}
}
}
}
Restart the client and ask it to run ignition_diagnose. You should get an all-green checklist,
aside from a warning about the bridge, which is the next step.
Generate a random secret, enable writes, and let the server install the bridge for you:
"env": {
"IGNITION_URL": "http://localhost:8088",
"IGNITION_API_TOKEN": "claude:YOUR_SECRET_HERE",
"IGNITION_BRIDGE_SECRET": "a-long-random-string",
"IGNITION_ALLOW_WRITES": "true"
}
Ask your assistant to install the bridge (this runs the bridge_install tool), then run
ignition_diagnose again to confirm the bridge check is green. See
docs/bridge.md for the manual install path and troubleshooting.
| Variable | Required | Default | Meaning |
|---|---|---|---|
IGNITION_URL | yes | none | Gateway base URL, e.g. http://localhost:8088 |
IGNITION_API_TOKEN | yes | none | API key, name:secret |
IGNITION_BRIDGE_SECRET | no | unset | HMAC secret for the bridge; bridge tools are disabled without it |
IGNITION_ALLOW_WRITES | no | false | Master switch for every mutating tool |
IGNITION_TLS_VERIFY | no | true | Set to false for self-signed dev gateways |
IGNITION_TIMEOUT_S | no | 30 | Per-request timeout, in seconds |
IGNITION_TAG_WRITE_ALLOWLIST | no | unset | Comma-separated glob patterns; tag writes outside them are refused |
IGNITION_ALLOW_WRITES=true and the
call passes confirm=true. Your assistant sets confirm after you approve the action.mcp-bridge logger. Secrets are never logged or echoed back.data/projects/; nothing outside that tree is
reachable.| Area | Tools |
|---|---|
| Diagnostics | ignition_diagnose, gateway_info, gateway_trial_status, gateway_trial_reset |
| Tags | tag_browse, tag_read, tag_write, tag_create, tag_config_export, tag_config_import |
| History | history_query, history_providers |
| Alarms | alarm_status, alarm_journal, alarm_acknowledge |
| Projects | project_list, project_get, project_create, project_delete, project_export, project_import, project_scan |
| Perspective | perspective_bootstrap_project, perspective_list_views, perspective_get_view, perspective_upsert_view, perspective_delete_view, perspective_validate_view, perspective_page_config_get/set, perspective_session_props_get, perspective_style_upsert, perspective_list_sessions |
| Gateway admin | gateway_modules, gateway_logs_query, gateway_logger_set_level, gateway_backup, gateway_performance, config_resource_list |
| Database | db_run_named_query, db_query |
| Bridge | bridge_install, bridge_status |
The server also exposes MCP resources the assistant can read to author valid Perspective views:
ignition://docs/view-schema and ignition://templates/view/{flex-basic,coordinate-basic,tag-bound-dashboard}.
See docs/perspective-authoring.md for the full writeup. In
short: the assistant reads the view-schema resource, starts from a template, validates offline
with perspective_validate_view, then deploys with perspective_upsert_view, which validates
again, writes the view, and triggers a project scan. A full round-trip example is in
examples/deploy-dashboard.md.
git clone https://github.com/jsgorana/ignition-mcp
cd ignition-mcp
python -m venv .venv && source .venv/bin/activate
pip install -e ".[dev]"
ruff check src tests # lint
ruff format --check src tests # format check
mypy src # type check
pytest tests/unit # unit tests, no gateway needed
python bridge/build_zip.py # rebuild the bridge project archive
# Live integration suite (needs a real 8.3 gateway with the bridge installed):
IGNITION_URL=... IGNITION_API_TOKEN=... IGNITION_BRIDGE_SECRET=... \
IGNITION_ALLOW_WRITES=true python tests/live/live_check.py
Built on the Model Context Protocol and its Python SDK, using httpx for HTTP. The ignition-sdk-examples repository was a useful reference while working out how Ignition's module and scripting APIs fit together.
MIT. See LICENSE.
This project is independent and community-built. It is not affiliated with, endorsed by, or sponsored by Inductive Automation. "Ignition" and "Perspective" are trademarks of Inductive Automation, LLC, used here only to describe compatibility. Test any write-enabled tool against a non-production gateway before pointing it at something that matters.