Listed from the MCP registry; nobody on Odel publishes it.
Ask your plant: live PLC data, alarms, history, OEE and reports from your on-premises PLCGateway.
Runs on your machine from its package; the steps are below.
At most: creates or changes data: records, files, settings.
Odel charges nothing per call. The publisher may charge for its own service.
Runs locally over stdio
This server isn't hosted — your MCP client launches it from a package registry. Use one of the commands below, or drop the config into your client (e.g. Claude Desktop).
Run
npx -y @plcgateway/mcp
MCP client config
{
"mcpServers": {
"plcgateway": {
"command": "npx",
"args": [
"-y",
"@plcgateway/mcp"
]
}
}
}MCP server for PLCs, CNC machines and SCADA. Ask an AI assistant about live machine data, alarms, history and OEE, and let it add devices, tags, screens and reports, on your own network.
PLCGateway is PLC gateway and SCADA software: it connects PLCs, CNC machines and controllers (Siemens S7, Modbus, Mitsubishi, Omron, Allen-Bradley, FANUC, OPC UA and more) and shares their data over OPC UA, MQTT, Modbus TCP and REST. Every PLCGateway product has an MCP server built in. This package is a small stdio bridge: MCP clients that start servers as a command (Claude Desktop, Claude Code, Cursor, Cline, Windsurf, …) run it, and it forwards everything to your PLCGateway on your network.
AI client ──stdio──▶ @plcgateway/mcp ──HTTP (your network)──▶ PLCGateway on your premises ──▶ PLCs & machines
Claude for Manufacturing is Anthropic's plugin for Claude Team and Enterprise. It drafts quotes, quality reports and breakdown investigations from business systems (Autodesk Fusion, Infor, Microsoft 365, Oracle NetSuite). It doesn't read the shop floor. Add PLCGateway next to it and those skills can work with live machine data (maintenance, SPC monitor and energy tools come with the Quality & Maintenance and Energy modules):
| Skill area | What Claude reads from PLCGateway |
|---|---|
| Diagnosing breakdowns | active_alarms, alarm_history, alarm_stats, query_history (sensor trends before the stop), list_maintenance |
| Investigating failed inspections | list_production_batches, query_history, spc_analysis, run_spc_monitor |
| Reporting on production | get_production_kpis, calculate_oee, energy_summary, generate_report |
/mcp endpoint to be reachable over HTTPS.Claude and Claude for Manufacturing are products of Anthropic. PLCGateway is an independent product and is not affiliated with or endorsed by Anthropic.
The tools come from the PLCGateway you connect to, so the list follows your edition and the rights of your token.
| Group | Tools |
|---|---|
| Context | get_site_context, system_status, help, list_protocols |
| Data | list_devices, list_tags, read_tags, query_history, write_tag, write_request_status |
| Alarms | active_alarms, alarm_history, alarm_stats, acknowledge_alarm, list_alarm_definitions |
| Production | calculate_oee, get_production_kpis, list_production_assets, list_batches, list_production_batches, set_batch_result |
| Screens and reports | list_screens, get_screen, list_symbols, run_screen_action, create_screen_draft, create_dashboard_draft, generate_report |
| Configuration (admin) | set_site_profile, test_device, create_device, update_device, create_tags, update_tags, define_production_asset, define_products, OPC UA certificate actions |
Full description: https://plcgateway.com/ai-mcp
All drivers are included in every licence, with no device or tag limit:
Siemens S7 · Modbus TCP/RTU · Mitsubishi MC · Omron FINS · Allen-Bradley EtherNet/IP · Beckhoff ADS · FANUC FOCAS · OPC UA and DA · IEC 60870-5-104 · IEC 61850 · DNP3 · BACnet
Data goes out over an OPC UA server, MQTT, a Modbus TCP server and a REST API. Details: https://plcgateway.com/protocols
write_tag and run_screen_action the assistant sends with the API
token or the MCP configuration token is held: nothing is written, and the tool answers pending approval with a
request id. Operators and administrators see the request at the top of every PLCGateway page (value, who asked, the
reason the assistant gave) and approve or reject it. Only a person signed in to PLCGateway can approve; the token
cannot approve its own request. Requests nobody decides on expire (10 minutes by default) and are never written. The
assistant checks the outcome with write_request_status. REST writes with the API token can be held the same way.api (approved by anna) wrote 230 to line1.SetTemp.For setup work (adding devices and tags) create the MCP configuration token in Settings and switch it off when done.
{
"mcpServers": {
"plcgateway": {
"command": "npx",
"args": ["-y", "@plcgateway/mcp"],
"env": {
"PLCGATEWAY_URL": "http://192.168.1.50:8080",
"PLCGATEWAY_TOKEN": "<your API token>"
}
}
}
}
claude mcp add --transport stdio \
--env PLCGATEWAY_URL=http://192.168.1.50:8080 \
--env PLCGATEWAY_TOKEN=<your API token> \
plcgateway -- npx -y @plcgateway/mcp
You don't need this package; connect straight to PLCGateway:
{ "mcpServers": { "plcgateway": { "type": "http", "url": "http://192.168.1.50:8080/mcp",
"headers": { "Authorization": "Bearer <your API token>" } } } }
plcgateway-scada --mcp-stdio (or plcgateway-connect --mcp-stdio) can be added as the command directly.
| Variable | Flag | Description |
|---|---|---|
PLCGATEWAY_URL | --url | PLCGateway address, e.g. http://192.168.1.50:8080 (/mcp is added if missing) |
PLCGATEWAY_TOKEN | --token | API token or MCP configuration token. Prefer the environment variable. |
PLCGATEWAY_TIMEOUT | --timeout | Request timeout in seconds (default 120) |
For HTTPS with your own certificate authority, set NODE_EXTRA_CA_CERTS=/path/to/ca.pem.
The bridge logs to stderr (visible in your client's MCP logs).
If PLCGateway cannot be reached when the client connects, the bridge stays up in offline mode with a single tool,
connection_status. Ask the assistant "why is PLCGateway not connected?" and it reports the reason. The bridge retries
by itself, and the plant tools appear once PLCGateway answers.
| Message | What to check |
|---|---|
PLCGateway not reachable | Address and port, firewall, PLCGateway running |
HTTP 401/403 | The token (Settings → API token); a regenerated token replaces the old one |
HTTP 404 | MCP is disabled in PLCGateway settings, or the URL points elsewhere |
The bridge in this repository is MIT licensed. PLCGateway itself is proprietary software, licensed separately.